Walk In Fridge Freezer Manager
There are real energy savings and hygine improvements that can be made on walk-in fridges and freezers, having doors left open or a jar for long periods of time and damaged or missing insulation curtains.
On average the WIFF Manager installation and a replaced or repaired insulation curtain, can give energy savings of 30% or over £1000.00 per annum.
Walk-in Fridge/Freezer energy reduction control key features:
Dynamic energy control, allowing for different setpoints for day use and nighttime when not in use, allowing for extra energy saving when fridge/freezer door remains closed at night.
Door left open alarm with visual and loud audible sounder.
Automatically blocking condenser operation when the door is opened.
Automatic anti condenser over cycling software to reduce duty cycle and reduce cooling system wear.
High internal temperature warning with loud audible sounder. Visual indication of current state of fridge/freezer via traffic light system.
10 Day audit log history for door open count, door left open time, internal temperature, energy savings and mains power outages.
Temperature control probe designed to replicate product temperature rather than air temperatures. This prevents rapid condenser cycling when warm air enters as soon as the door is opened.
Alarm mute button for stocktaking or loading (can only be used once in any 8-hour period).
24-hour Control bypass button for fridge/freezer allowing for servicing/repair/bypass etc.
24-hour auto learn, allowing the energy control algorithm to learn the individual characteristics of each fridge or freezer to achieve the best possible energy reduction curve.
Pin protected so only authorized service engineers can change settings.
Auto door opening facility with easy open control option.
Auto PIR activated internal LED light option.